Series RMA

The Athena Series RMA is a microprocessor-based, single-zone temperature controller specifically designed for runnerless molding applications. It features an easy-to-use operator keypad, two LED displays, and discrete indicators for heat output, alarm, degree F/C indication, manual, and closed loop mode.

  • Compatible with industry standards control modules and mainframes
  • Accepts Type J thermocouple
  • Bumpless auto/manual transfer
  • CompuStep® bake out feature prevents moisture at startup
  • Built-in loop break for open heater, shorted triac, reversed or shorted thermocouple
  • Open thermocouple break protection with jumperselectable shutdown or average power output based on operation
  • Preset alarms at 30°F (17°C)
  • SafeChange™ “hot swap” feature allows safe removal and replacement of module
  • CE compliant

Series RMT

The Athena Series RMT is a microprocessor-based, dual-zone temperature controller specifically designed for runnerless molding applications effectively doubling the zone count per module without doubling the price. It features two easy-to-use operator keypads, four LED displays, and discrete indicators for heat output, alarm, degree F/C indication, manual and closed loop mode.

  • Accepts Type J thermocouple
  • Bumpless auto/manual transfer
  • CompuStep® bake out feature prevents moisture at startup
  • Built-in loop break for open heater, shorted triac, reversed or shorted thermocouple
  • Open thermocouple break protection with jumperselectable shutdown or average power output based on operation
  • Preset alarms at 30°F (17°C)
  • SafeChange™ “hot swap” feature allows safe removal and replacement of module
  • CE compliant
  • 15 amps per zone

Series RMC


The Athena Series RMC brings new and highly productive benefits to injection molders looking for a modular hot runner controller that’s flexible, easy to set up, and simple to operate. Using the popular Modbus® communications protocol, the Series RMC gives users the ability to set or change all zones, either remotely from a desktop computer, or (with the ALL command) from any other individual RMC module in the mainframe.

  • Choice of three default modes for open thermocouple condition
  • Built-in triac safety protection
  • Accepts J or K thermocouple input (jumper selectable)
  • SafeChangeTM “hot swap” feature allows safe removal and replacement of module
  • CompuStep® bake out feature prevents moisture at startup
  • Built-in loop break, short, open, and reverse thermocouple protection
  • Boost” mode for temporary % of power output increase
  • Ground-fault protection
  • Adjustable setpoint limits
  • Stores highest temperature detected
  • Current monitor feature displays average current to load
  • CE compliant

Series RMB

The Athena Series RMB is a microprocessor-based, single-zone temperature controller specifically designed for runnerless molding applications. It features an easy-to-use operator keypad, two LED displays, and three discrete indicators for heat-current, alarm and manual mode. Athena’s mainframes are compatible with all D-M-E Company’s G SERIES and SMART SERIES,® ITC, MCS, YUDO® and INCOE® brand mainframes.

  • Accepts Type J or Type K thermocouple input (jumper selectable)
  • Auto-tuning, with adjustable proportional band and rate
  • Bumpless auto/manual transfer
  • CompuStep® bake out feature prevents moisture at startup
  • Built-in loop break, short, open, and reverse thermocouple protection
  • Built-in triac safety protection
  • Ground-fault protection
  • Preset alarms at 30° F (17°C)
  • Jumper-selectable soft-start mode
  • Current monitor feature displays average current to load
  • SafeChangeTM “hot swap” feature allows safe removal and replacement of module
  • CE compliant

DYDAC MICROPROCESSOR BASED HOT RUNNER TEMPERATURE CONTROLLER

  • Microprocessor Based Auto – Tune PID Temperature Controller
  • Accepts J ,K ,R, S, T Type Thermocouple
  • ( Soft Start) bake out feature prevents moisture at startup
  • Auto/Manual Transfer
  • Accuracy of +/- 1 Deg. C.
  • Internal Solid state triac, triggered by Phase angle Firing.
  • Dual displays for Process and Set Temperatures
  • High Speed Fuses 16 A protection Fuses.
  • New Series with Short Circuit protection of Power Modules by C Curve MCB
  • Latest Generation PID algorithm.
  • Power Controller can take 3600 or 7200 Watts at 240 VAC
  • In case of thermo couple Failure you can set the Power Manually by not stopping the production.
  • Heaters life is extended to 10 times.
  • PID Temperature controller has bar graph indication of percentage output going to heaters.
  • PID Temperature Controller is CE Compliant and Phase Angle Power Controller is CE Compliant.
  • The Power Controllers are Phase Angle Fired and are Variable Power Controllers which gives as much Power to the Heaters as required to maintain the Temperature thus saving the Energy ( Energy Conservation at Set Point) and increasing the life of Heaters less Production Break Down.
  • Alarm Option for over shooting and under shooting of Temperature. In case Thermocouple Fails it will give Alarm

Selection of Heater Current Load

  • 16 Amps
  • 32 Amps

MOLD POWER AND THERMOCOUPLE CABLES

More specifically designed for the plastic industry by process of hot runner injection molding, Dydac manufactures mold power and mold thermocouple cables designed specifically for your mold and temperature controller connections.Working hand-in-hand with processors as well as mold makers, Dydac can provide virtually any configuration or adaptor cable that is best suited for your individual process. Dydac can assist with cable design, cable and connector selections. With our just-in-time manufacturing capabilities, Dydac can produce cables on demand.MOLD POWER CABLESMold power cables are used to connect the mainframe to the power input connector located on the mold. All cables are wired for 5, 8, or 12 (rated @ 15A) zones as well as units working on 30A. Mold power cables are available in any length, 10 and 20 feet are standard stocked cables.

NO. OF ZONES 10 FEET CABLE 20 FEET CABLE
5 PC5Z-10 PC5Z-20
8 PC8Z-10 PC8Z-20
12 PC12Z-10 PC12Z-20

MOLD THERMOCOUPLE CABLES

Mold thermocouple cables are used to connect the mainframe to the thermocouple connector on the mold. Cables are wired for 5, 8, or 12. In most cases the connections on the controller remain constant, while the connector on the mold end can vary. Mold thermocouple cables are available in any length, 10 and 20 feet are standard stocked cables.

NO. OF ZONES 10 FEET CABLE 20 FEET CABLE
5 TC5Z-10 TC5Z-20
8 TC8Z-10 TC8Z-20
12 TPC12Z-10 TPC12Z-20

Features

1. Soft start – bake out feature prevents moisture at start up.

Ratings

1. Single Phase – 30, 40, 60, 80, 100,120 Amperes
2. Three Phase Star/Delta-30, 50, 70, 90, 150, 200, 250, 300,350, 400 Ampers

Input Control: 4 – 20 mA DC, )-10 V, Potentiometer

Dydac Controls Thyristor SCR Power Controllers |some typical applications:

  • Large tank heating and mechanical relay replacement.
  • Thermoforming, textiles, industrial furnaces and ovens, extruders, kilns, chemical process heating, fast water heat.
  • Paper and pulp drying, packaging machines, pharmaceutical processes, infrared ovens and dryers.
  • High-temperature ovens and furnaces, kilns, glass, ceramics & high-temperature alloys.
  • High-speed paper and ink dryers, high temperature IR heating, high temperature materials processing.
  •  Phase angle proportional control. No temperature or power cycling
  • I2T Rectifier fuses standard
  • Isolated SCR’s
  • Integrated thermal/mechanical design saves panel space
  • Voltage protection – MOV capacitance
  • 30 to 400 Ampere current ratings.
  • Easy to install, test, service

Specification

Insulation way Distance between the input terminal LED instrutions Load Current Load Voltage Model
Photoelectric three-terminal LED 30- 400A 40-480VAC AXIS E Series
two-way thyristor switch

Performance and related technical parameters

Product Model AXIS TPR – 3 – 30A, AXIS TPR – 3 – 40A
AXIS TPR – 3 – 60A AXIS TPR – 3 – 80A
AXIS TPR – 3 – 100A AXIS TPR – 3 – 120A
AXIS TPR – 3 – 150A AXIS TPR – 3 – 200A
AXIS TPR – 3 – 250A AXIS TPR – 3 – 300A AXIS TPR – 3 – 400A
Load voltage 40-480VAC Single Phase
Max Load current 30A, 40A. 60A, 80 A, 100 A, 120 A, 150A
200 A, 250 A, 300 A
Isolation bet.In & out ≧2000VAC
Isolation to case ≧2500VAC
Control Signal 4- 20 mA DC 100 OHMS
off-state leakdge ≦0.5mA
off-state dv/dt 300v/Us
on or off time 10mS
Frequenty range 47/63Hz
Status indicator LED
Operating temperature -40~80℃

Applications

  •  Switching of Heater by Temperature Controller
  •  Heater applications in Furnace/Oven industry
  •  Plastic Processing Machinery, Injection Molding, Blow Molding and Extruder
  •  Solder Screen Printers, Solder Wave / Re-flow Machine
  •  Solid and Liquid Packaging Equipments and Machinery
  •  Medical Equipments
  •  Texturising Machinery
  •  Printing Machinery
  •  Controlling of Infrared Heaters (Inductive Heaters) by Analog SSRs.

Dydac®offers wide range of Thyristor Power Controllers in DOUBLE PHASE.

Features

1. Soft start – bake out feature prevents moisture at start up.
2. Current Limit , Phase Loss Trip, Over temperature Trip.
3. Microprocessor Digital Programmable Thyristor Power Controller with Percentage Display. Program setting of Current Limit, Soft start etc by front keys.

Ratings

1. Double Phase – 25 , 34, 59, 70, 90, 150, 200 , 250, 300 Amperes

Dydac Controls Thyristor SCR Power Controllers | A sample of some typical applications:

  •  Plastic Extruders , Plastic Injection Moulding machines
  •  Thermoforming, textiles, industrial furnaces and ovens, extruders, kilns, chemical process heating, fast water heat.
  •  Paper and pulp drying, packaging machines, pharmaceutical processes, infrared ovens and dryers.
  •  High-temperature ovens and furnaces, kilns, glass, ceramics & high-temperature alloys.
  •  Large tank heating and mechanical relay replacement.
  •  High-speed paper and ink dryers, high temperature IR heating, high temperature materials processing.
  •  Primary of transformer-coupled loads.
  •  Phase angle proportional control. No temperature or power cycling
  •  I2T Rectifier fuses standard
  •  Isolated SCR’s
  •  Integrated thermal/mechanical design saves panel space
  •  Voltage protection – MOV capacitance
  •  10 to 400 Ampere current ratings. Other Ratings Over 400 Amps Possible.
  •  Easy to install, test, service

The Dydac Thyristor Power Controller is a heavy duty, fully Digital two phase power control unit for controlling the voltage applied to loads such as heating elements, thus, allowing temperature control while eliminating contactor switching and over/under heating. The first in a series of Digital ( SCR ) Power Controllers incorporating protection functions. Built in switching methods are:

1. Phase Control Firing2. Zero Crossing Firing

Range:

15 A – 400 A , 220-1200V,

Advantages at a glance

  •  Fully digital Thyristor
  •  Analog Thyristor
  •  Phase Control and Zero Crossing
  •  Current: 15 – 300 A (consult us when higher ratings are needed)
  •  Voltage: 230- 500 V 50/60Hz
  •  Cooling Method: Natural or Forced air
  •  Ambient. Temp: 0 – 50°C
  •  Continuous Duty
  •  Two controlled phases
  •  C.T.’s
  •  Input, 4-20mA or 0-20mA, 0-10VDC
  •  Digital display

Control Input: Analog (4-20mA/0-20mA/1-5V/0-5V)Indicating of analog signal.Automatic Output-limit cognition of external volume or internal limit setting.Various alarm mode(over current, line failed, over temperature, load unbalance)Fault alarm output / Run outputProgrammable soft start.True RMS current displayAuto/Manual mode operation is possible.Over current tripOutput Current Limit FunctionBuilt-in watch timerHeat-sink temperatureLoad unbalanced level is programmable Compact size

LEDs

  • Over Current
  • Over Temperature
  • Alarm
  • Trip

Connection types

  • Double Phase

Protection functions

  • Under & Over current
  • Shorted SCR
  • Heat sink over temperature Trip & Alarm
  • Internal failure

The SCR control can deliver electrical power to heaters in several ways: phase angle fired, zero voltage switched and on/off control.Product can be changed or modified without Notice

Power Calculation

When selecting the correct sized SCR power controller, rate the SCR for at least 110% of the heater load. Heaters and power lines have tolerances that can swing on any given day or location.

Double PhaseWATTS÷ VOLTS= AMPS

Example: 18,000W ÷ 440V = 40.9 A

AMPS x VOLTS= Watts

Example: 40.9Ax 480V = 18,000W

AMPS x VOLTS x 1.73 = Watts

Example: 60A x 480V x 1.73 = 49,824

WExample: 18,000W ÷ 240V = 75A